| Sign In | Join Free | My ecer.com.ru |
|
Holding Current (Ih) : 5mA
Current - Gate Trigger(Igt) : 200uA
Voltage - On State(Vtm) : 1.35V
Current - On State(It(RMS)) : 800mA
Peak off - state voltage(Vdrm) : 600V
SCR Type : -
Operating Temperature : -40℃~+125℃
Gate Trigger Voltage (Vgt) : 800mV
Description : 5mA 200uA 600V SOT-223 SCRs RoHS
Mfr. Part # : X00619MN5AL2
Model Number : X00619MN5AL2
Package : SOT-223
The X00619 SCR is designed for on/off functions in applications where high gate triggering current is not available. It offers optimized forward voltage drop and inrush current capabilities, leading to reduced power losses and enhanced reliability in demanding environments. This device is ideal for limited gate current topologies, ground fault circuit interrupters, overvoltage crowbar protection in power supplies, protection in electronic ballasts, capacitive discharge ignitions, and ignitors for lighting and ovens.
| Part Number | IT(RMS) | VDRM/VRRM | IGT | Tjmax. | Package |
|---|---|---|---|---|---|
| X00619 | Up to 0.8 A | 600 V | 30 to 200 A | 125 C | TO-92, SOT-223 |
| Symbol | Parameter | Value (TO-92, TL = 83 C) | Value (SOT-223, Tamb = 107 C) | Unit |
|---|---|---|---|---|
| IT(RMS) | On-state RMS current (180 conduction angle) | 0.8 | - | A |
| IT(AV) | Average on-state current (180 conduction angle) | 0.5 | - | A |
| ITSM | Non repetitive surge peak on-state current (tp = 8.3 ms) | 10 | - | A |
| I2t | I2t value for fusing (tp = 10 ms) | 0.4 | - | As |
| dV/dt | Critical rate of rise of on-state current | 50 | - | A/s |
| IGTM | Peak gate current (tp = 20 s) | 1 | - | A |
| PG(AV) | Average gate power dissipation | 0.1 | - | W |
| Tstg | Storage junction temperature range | -40 to +150 | C | |
| Tj | Operating junction temperature range | -40 to +125 | C | |
| Symbol | Parameter | Test Conditions | Min. | Max. | Unit |
|---|---|---|---|---|---|
| IGT | Triggering gate current | VD = 12 V, RL = 140 | 30 | 200 | A |
| VGT | Gate trigger voltage | VD = 12 V, RL = 140 | - | 0.8 | V |
| VGD | Gate non-trigger voltage | VD = VDRM, RL = 3.3 k, RGK = 1 k, Tj = 125 C | 0.2 | - | V |
| IH | Holding current | IT = 50 mA, RGK = 1 k | - | 5 | mA |
| IL | Latching current | IG = 1 mA, RGK = 1 k | - | 6 | mA |
| dV/dt | Static dV/dt | VD = 67 % VDRM, RGK = 1 k, Tj = 125 C | 40 | - | V/s |
| VTM | On-state voltage | ITM = 1 A, tp = 380 s | - | 1.35 | V |
| IDRM | Off-state current | VDRM = VRRM, RGK = 1 k, Tj = 25 C | - | 1 | A |
| IRRM | Off-state current | VDRM = VRRM, RGK = 1 k, Tj = 125 C | - | 100 | A |
|
|
SCR device ST X00619MN5AL2 suitable for overvoltage crowbar and ground fault interrupter applications Images |